Resolving Common Issues
If you encounter issues placing hangers or supports using the MEP Hangers solution, this article addresses common mistakes that prevent successful insertion.
Report Window
When a configuration fails, the software typically generates a report window indicating the MEP elements where hangers couldn't be inserted.

You can select a row in the report and click Show Element to highlight the element in the view for examination. If the configuration fails for only a few selected MEP elements, you can click OK to proceed where possible or Cancel to undo the whole operation.
The report window also provides the Configuration Name and the Rule Name associated with the failure.
Some configurations can have multiple rules and this is what the Rule Name column refers to.

If you encounter an error message and are unsure how to resolve it, or if no hangers are being inserted without any error message, follow the steps below:
1. Choosing the Wrong Configuration
After selecting MEP elements in your view and clicking Insert Hangers, you need to select which configuration to apply. In sample configurations, the default ones for all MEP categories attach hangers from the MEP element to the Floors or Roofs above. All these configurations start with “01”, for example: 01.1_M_Pipes – Hangers to Floors-Roofs Above.

Using this configuration when there are no Floors or Roofs near the MEP elements will result in an error. Similarly, an error will appear if you try to attach hangers to Floors or Roofs but use a Wall Supports configuration.
Solution:
Choose an appropriate configuration (based on its name) for your use case. The configurations for the most common scenarios are displayed first.
To learn more about what a configuration does, click Edit in the Insert Hangers window (or go to Hanger Configurations in the MEP Hangers toolbar). There you will find a Description field for each configuration, briefly explaining its purpose.
2. Structural elements aren't found
Another frequent error occurs when the structural elements, specified in the configuration, aren’t located within the project. These structural components serve as attachment points for the hangers (such as floors, roofs, walls, and other supports in the case of multi-level hangers). Without these elements, the software cannot calculate the lengths of rods (or other vertical structural members) or determine where hangers should be positioned.
Let's consider a straightforward example: You're attempting to place hangers for a run of pipes beneath a floor. These pipes are 802mm away from the floor, measured from the top of the pipe:

Suppose the Structure Selection in your configuration looks like this:

Running such a configuration would lead to an error. The section highlighted in blue indicates the categories the software searches for to attach hangers.
You should check the category of structural elements above the pipes. If it’s a linked file, you can still select the element by hovering the cursor over it and clicking Tab until it's highlighted (ensure that Select Links and/or Select Pinned Elements are enabled).
Solution:
If the category differs from what you have in the configuration (blue section), tick the respective checkbox in the configuration. You can also select multiple categories if necessary. If the category is not listed, there's a workaround at the bottom of this article.
It could also be the Searching Direction (green). This setting determines the direction in which the software searches for structural elements. For instance, 'Down' indicates that it's searching below the pipes.
Solution:
In this example, you should set it to 'Up' because the floor is above the pipes.
The 'Searching Distance' determines how far the software will search for structural elements.
Solution:
To locate the floor in this example, let’s increase the value. It needs to be at least 803 mm. To avoid frequent configuration adjustments, let’s set it to a safe value of 2000mm.
Settings highlighted in grey are additional filters you can set. If the filter criteria aren’t met, this can also result in an error. Be sure to review these filters as well.
After modifying these settings, the configuration will be successful.

Please note that this example represents a worst-case scenario, and most of the issues can be avoided by selecting an appropriate configuration from the start.
Additionally, some settings can affect the runtime of a configuration. Therefore, it's not recommended to select all available categories or set an extremely large max Searching Distance value. You can find more information about the individual settings in this article.
3. Hangers are placed but not visible in the floor plan
If you run a configuration in a floor plan and no hangers appear in the view, and no error message is displayed, the hangers may have been inserted but are not visible in that view. This is a common issue when using the Structural Connections library of hangers.
Solution:
If using the Structural Connections library:
Switch to a 3D view to check if hangers are present. If they are, adjust the cut plane height in the floor plan to make them visible. Keep in mind that this adjustment may affect the visibility of other elements.
Alternatively, use the Mechanical Equipment library for hangers. Hangers in this category are visible in floor plans even when above the cut plane, unlike those in the Structural Connections category. Before doing so, refer to this article on the differences between StrC and MeEq category hangers.
If using Mechanical Equipment library:
Other settings in Visibility/Graphic Overrides may be preventing hangers from being visible. If you can locate hangers in other views, try adjusting visibility settings in the original view.
3. Filtering MEP elements
In the configuration, you can also establish filters for MEP elements. You can use any property of the MEP element to filter by.
For instance, in this example, I’m filtering only the pipes larger than 200mm in diameter. However, since the pipes are smaller, running this configuration wouldn’t place any hangers. A report window wouldn’t appear either, as the configuration precisely executes its intended function – placing hangers only if the diameter exceeds 200mm.

Solution: Simply modify or remove the filters.
Note that these filters are often used with Rules to place different hangers or adjust spacing based on the properties of the MEP element. Some rules are intentionally designed to "fail." Be cautious not to delete filters that were created for specific tasks.

4. Spacing
In rare cases, the Spacing options can trigger an error, particularly for Layout Direction/Layout Rule sets that include 'Start Offset' or 'End Offset' options. For example, if a pipe is 100mm in length and the Start Offset is set to 200mm, the software will attempt to place a hanger 200mm from the start of the pipe, resulting in an error.

Solution:
Adjust the 'Start Offset' or 'End Offset 'value or consider using a different Layout Direction and Layout Rule.
To prevent this issue in the future, it's advisable to create a Rule specifically for short elements. In the provided example, the configuration includes 2 Rules: one for short pipes, which places a hanger in the middle of the pipe, and another for other pipes, which follows typical spacing settings.

5. Other issues (and a workaround)
If none of the points mentioned earlier improved your situation, the error could be caused by other combinations of settings. You can read more about configuration settings in depth in this article.
It can also be caused by unrecognized objects in the Revit model. However, there's a workaround that can address most other potential issues.
Solution:
Create some 'placeholder'/'dummy' structural elements in the active MEP model.
For instance, if the software isn’t detecting a floor above (and you’ve addressed all the points in #2), create a Floor element and align it with the architectural/structural floors from the linked files. Then, set the 'Search in Project' option to 'Current Project' only. This ensures that the software will only locate the 'placeholder' Floor, to which a hanger can be attached.

Afterwards, you can easily hide these 'placeholder' elements from your floor plans or 3D views using Visibility/Graphic Overrides.
This method is also applicable when linking IFC structural/architectural files, which may have unusual categories assigned. For example, the floors or walls might be classified as Generic Models. While it’s also possible to address this through 'Import IFC Options' in Revit, the 'placeholder' solution may sometimes be quicker.
Conclusion
Following these steps should allow you to insert hangers/supports into your Revit model. If the problem persists, contact us at [email protected].