Insert Fire Dampers
After configuration (mapping) is set up, users must perform the Revit "Interference Check" function and run it for ducts and any structure types that might require fire dampers.
Save the interference check file by exporting the results.
Select "Insert/Update Fire Dampers" in Cut Opening to open the insertion menu.
In the newly opened window, select the recently exported interference check file. This will lead to the next step of fire damper insertion.
Clicking "Next" will lead to the Opening Table, which in this case will be the fire damper insertion table.
Clicking "OK" will start the fire damper insertion process. Fire dampers will be inserted only for the clashes actively visible in the table.
Please read the "Controlling the Opening Table" post to learn how to manage the opening table.
Last updated