Skip to content
For the complete documentation index, see llms.txt. This page is also available as Markdown.

Element Identification and Mark

Plate/Rim Joist/Girders


This information also applies to the Studs/Joists/Columns tab, but the settings apply to Stud, Joist, and Column elements instead.

This tab lets you set and customise various BTL/BTLx part attributes for Plate, Rim Joist, and Girder elements in your framing assembly.


Common


Common tab lets you control various settings related to element marking, from element positioning lines to aid manual assembly to element tag location.

Element Identification and Mark window. Common tab

  • Print Plate Mark (x) on (x) Side of Frame - controls activation and location of Mark, configured in Mark tab. Unticking results in no mark being printed on the element by the machine. Once ticked, you can also choose which side of the element the Mark should appear on, relative to how it appears in Revit.

    • Left - side number 2

    • Right - side number 4

    • Inner - side number 6

    • Outer (default) - side number 5

    • Studs -


  • Print Plate Position Mark (x) on Connected Element (x) Side of Frame -

    • Left - side number 2

    • Right - side number 4

    • Inner - side number 6

    • Outer (default) - side number 5

    • Connected - line will be placed on connected element on the side where two elements meet

Orientation cube


  • Move the overlapping Position Mark -

  • Project (x) Plate Left side layout Mark to (x) Side if Frame -

    • Outer -

    • Inner -

  • Project (x) Plate Right side layout Mark to (x) Side if Frame -


  • Print Plate Position Lines - prints position lines of studs, joists and columns on the plates and, in the case of noggings, prints lines on the studs.

  • Rotated Plates for Connected Elements are evaluated -

  • Plates which cut Connected Elements are evaluated -


Mark


Mark tab allows customisation of elements' 3/4-060-X Marking / Labeling command, used to print the main element identification mark. You can combine various available Revit parameters to create the desired mark format from the parameter values. The resulting value will be used in the P15: Text field.

Parameter Combination Table

Here are the options for configuring a mark by combining different parameters:

  1. Available Parameters - lets you choose available valid parameters to form your mark from

  2. Mark = - here you can see the parameters currently selected to be used to combine the mark from

    • Parameter Name - shows the parameter name for reference

    • Prefix - here you can enter the desired prefix to be used before the selected parameter value

    • Suffix - here you can enter the desired suffix to be used after the selected parameter value

  3. Add/Remove - these buttons let you add or remove selected parameters from either table

  4. Up/Down - these buttons let you move parameters in the Mark = table to reorder them


Marking Text Settings - here are the options to control placement of the mark on the element:

  • Text Height - value is used to fill the P13: Height of text command field.

  • Text Position Offset - value is used to fill the P01: Distance from beam start to reference point command field.

  • Text Cross-Meas Offset - value is used to fill the P02: Distance from reference edge to the reference point command field.

  • Horizontal - value is used to fill the corresponding P04: Position and alignment of the text command field.

  • Vertical - value is used to fill the corresponding P04: Position and alignment of the text command field.

  • Text - value is used to fill the corresponding P04: Position and alignment of the text command field.


Position Marking


Position Marking tab allows customisation of elements' 3/4-060-X Marking / Labeling commands used to indicate positions of the connecting elements. You can combine various available Revit parameters to create the desired mark format from the parameter values. The resulting value will be used in the P15: Text field.

Parameter Combination Table

Here are the options for configuring a mark by combining different parameters:

  1. Available Parameters - lets you choose available valid parameters to form your mark from

  2. Mark = - here you can see the parameters currently selected to be used to combine the mark from

    • Parameter Name - shows the parameter name for reference

    • Prefix - here you can enter the desired prefix to be used before the selected parameter value

    • Suffix - here you can enter the desired suffix to be used after the selected parameter value

  3. Add/Remove - these buttons let you add or remove selected parameters from either table

  4. Up/Down - these buttons let you move parameters in the Mark = table to reorder them


Marking Text Settings - here are the options to control placement of the mark on the element:

  • Text Height - value is used to fill the P13: Height of text command field.

  • Horizontal - value is used to fill the corresponding P04: Position and alignment of the text command field.

  • Vertical - value is used to fill the corresponding P04: Position and alignment of the text command field.

  • Text - value is used to fill the corresponding P04: Position and alignment of the text command field.


Attribute tabs


  • Module Mark - allows customisation of parts' Module number attribute value.

  • Annotation - allows customisation of parts' Annotation attribute value.

  • Element Number - allows customisation of parts' Element number attribute value.

  • Group - allows customisation of parts' Group attribute value.

  • Assembly Number - allows customisation of parts' Assembly number attribute value.

Parameter Combination Table

Here are the options for configuring a mark by combining different parameters:

  1. Available Parameters - lets you choose available valid parameters to form your mark from

  2. Mark = - here you can see the parameters currently selected to be used to combine the mark from

    • Parameter Name - shows the parameter name for reference

    • Prefix - here you can enter the desired prefix to be used before the selected parameter value

    • Suffix - here you can enter the desired suffix to be used after the selected parameter value

  3. Add/Remove - these buttons let you add or remove selected parameters from either table

  4. Up/Down - these buttons let you move parameters in the Mark = table to reorder them


Element Filtering


  • Structural Framing – lets you create a filter for framing elements that need to be excluded from exporting. Activates by ticking the option Automatically skip filtered out Elements in Common Settings.

Last updated

Was this helpful?